Which products count as temperature-sensitive
WHO uses the term time- and temperature-sensitive pharmaceutical product for any product that, when not stored or transported within set environmental conditions or time limits, degrades to the point that it no longer performs as intended.
Reading the storage statement
In European product information, a medicine whose long-term stability is shown at 5 °C ± 3 °C carries the statement "Store in a refrigerator", often with "Do not freeze". The product information also gives the range, for example 2 °C to 8 °C. A stricter statement, "Store and transport refrigerated", is reserved for exceptional cases.
In transit
- Qualified packaging. WHO guidance expects the packaging system to keep the product within the range its stability profile needs for the whole journey.
- Monitoring. Freeze indicators or electronic temperature loggers travel with the goods, and their status is checked and documented on arrival.
- Secure packing. Packing should reduce the risk of theft and tampering, so the receiver can see the goods were not opened in transit.
Temperature excursions
A temperature excursion is any event in which the product is exposed to temperatures outside its storage or transport range. WHO guidance says product stability data must show how long an excursion during transport is acceptable, and its distribution guidance asks for written procedures for investigating temperature deviations. Agree with your supplier, before shipment, what happens if the logger shows an excursion.
Records
Keep the temperature records for each shipment. WHO's distribution guidance asks for records that are accurate, legible and traceable, and distribution records detailed enough to allow a recall when required.
Questions to ask before you order
- How will the shipment be packed, and for how long does the packaging hold the range?
- Which indicator or logger travels with the goods, and who reads it on arrival?
- What happens if the reading shows an excursion?
- Which documents and temperature records come with the shipment?
- Does your import route need any approval before a refrigerated consignment ships?
We supply cold-chain products, including those stored at 2 to 8 °C. See Cold-Chain Medicines or send your enquiry with the product and destination.
Sources
- World Health Organization, Model guidance for the storage and transport of time- and temperature-sensitive pharmaceutical products (Technical Report Series 961, Annex 9; glossary and sections 6.2, 6.5.4, 6.8.3, 6.9 and 9.3.1): who.int
- World Health Organization, Good storage and distribution practices for medical products (Technical Report Series 1025, Annex 7; sections 17.6, 18.16 and 18.40): who.int
- European Medicines Agency, Guideline on declaration of storage conditions (CPMP/QWP/609/96/Rev 2): ema.europa.eu (PDF)